| Model |
|
E-500A |
E-650A |
| Capacity |
VA
/ Watts |
500VA/250W |
650VA/325W |
| Input |
Voltage |
110/
115/120Vac or 220/230/240Vac |
| Voltage
Range |
86Vac~
144 Vac or 172Vac~288 Vac (-25%) |
| Frequency |
47Hz~
53Hz or 57Hz~63Hz |
| Output |
Voltage
Regulation(Batt. Mode) |
110/
115/120Vac or 220/230/240Vac +/-10% |
| Frequency |
50Hz
or 60Hz +/-1Hz |
| Transfer
Time |
<6ms
(typical) |
| Waveform |
Simulated
Sinewave |
| Outlets:IEC-320/NEMA
5-15R |
3
/ 2
|
| Battery |
Battery
Type |
12V/4.5AH*1PC |
12V/7AH*1PC |
| Recharge
Time |
5
Hrs to 90% after complete discharge |
| User's
Replacement |
No |
| Battery
Protection |
Over
discharge protection,short circuit protection by fuse |
| Advanced
Battery Management |
Yes |
| Battery
Back-up Time |
10mins
(Load with 1 PC) |
20mins
(Load with 1 PC) |
| Function |
Display |
LED
status indicators for line on(Green),back-up(Yellow),UPS cut off
(Red) |
| Alarm |
Buzzer
on for Back-up mode,Battery low |
| Output
Short Protection |
AC
fuse and electronic circuit(Line mode);electronic circuit (Back-up
mode) |
| Modem/Phone
Protection |
RJ-11 |
| Lightning/Surge
Protection |
240joules
|
| AVR
(Auto. Voltage Regulation) |
Yes |
| DC
Start Function |
Yes |
| Auto.
Restart UPS |
Yes |
| Over
/ Under Voltage Protection |
Yes |
| Environment |
Safety
Standard |
CE
(EN50091-1,EN62040-1-1) |
| EMC
Standard |
FCC Part 15 Class
B,CE (EN50091-2,EN55011,EN61000-3-2,EN61000-3-3) |
| Operating
Temperature |
0°
~ 40°C |
| Relative
Humidity |
0
~ 95%, non-condensing |
| Audible
Noise |
<40
dB at 1M |
| Physical |
Dimension(D*W*H) |
265*90*176 mm |
| Net
Weight |
5kgs |
6kgs |
DESIGN,
MANUFACTURE,
SERVICES |
|
ISO-9001-2000 |
| Warranty |
|
1
year |